Direct Hotline: +91 98102 37952
Rangpuri Near Shiv Murti, NH-8, New Delhi
ISO 9001:2015 Certified Manufacturer
Repeating barrel-vault tensile canopy over a parking area at a Minda Group plant, built by Ekra Decor
ESTABLISHED 1998 • DESIGN · FABRICATION · INSTALLATION

Modular Tensile Structure Manufacturer

Tensile canopies built from a single repeated bay or unit — a barrel-vault bay, a conical module, an inverted umbrella — so a large area is covered quickly on a predictable programme, and the canopy can be extended later. Built by Ekra Decor since 1998.

  • One bay, engineered once, repeated
  • Fast, predictable installation
  • Extend the canopy later
  • Engineered to IS 875, IS 800 & IS 456
Practising since 1998
ISO 9001:2015 certified
Design to maintenance, one team
Pan-India project execution
Trusted Nationwide

Engineering Trusted by India’s Leading Names

28+ years delivering tensile structures for corporate campuses, industrial groups, and institutional developments — built with fabric technology from the world’s leading membrane manufacturers.

Corporate & Institutional Clients
Material Technology Partners
Modular & Re-erectable

What makes a tensile structure modular

A modular tensile structure is built from repeating bays with bolted connections, so it can be extended, reconfigured or relocated later without cutting or re-welding on site. You give up a little of the freedom of a one-off design in exchange for speed and flexibility.

Standard bays

The structure is set out on a grid — a fixed bay width and a small number of standard heights and spans. Components repeat, which cuts drawing time, speeds fabrication and makes spares and future extensions straightforward.

Bolted, not welded on site

Every site connection is a bolted plate or a pinned casting. The frame goes together with hand tools and a crane, and it comes apart the same way. Nothing about the erection is permanent.

Foundation options

Cast-in bases for a permanent installation; ballast blocks or ground screws where the structure may move or the ground must not be disturbed. The foundation choice is what usually decides whether a modular structure is treated as permanent or temporary for approvals.

Add, move, reconfigure

Extra bays bolt onto the ends; a run can be shortened; the whole structure can be dismantled, transported and re-erected on another site. That suits leased land, campuses built in phases, event grounds and any operation whose footprint is likely to change.

The trade-off

A modular grid will not give you the sweeping one-off geometry of a fully custom membrane. Where the form is the point, a custom fabric structure is the better route.

Related: portable fabric structures and fabric buildings. Tell us the site and how it may change for a modular layout.

Modules

Modular tensile structure types

A modular tensile structure is one pre-engineered bay or unit, repeated. The design effort goes into one module; the rest is multiplication.

Repeating barrel vault

One curved bay spanning between two column lines, repeated along the length — for parking rows, walkways and covered yards.

Conical module grid

A grid of identical cones covering a large footprint while keeping a peaked roofline — for plazas and event areas.

Inverted umbrella

Each unit stands on one central column with its own drainage; a grid of them covers a plaza on a clean pattern.

Hypar bay array

Repeating saddle bays over a regular column grid — efficient over a large rectangular area.

Related: car parking tensile shades, two-wheeler parking sheds, custom fabric structures.

Specification & Options

What is specified

The specification is really the specification of one module — once that is fixed, the canopy is a count of how many.

Specification choices
ElementOptions
ModuleBarrel-vault bay, conical unit, inverted umbrella, or hypar bay
MembranePVC or PVDF for most work; PTFE-glass where permanence or a fire class applies
FrameIdentical galvanised steel bents or units, sized once for the worst-case bay
GridSet to the site — parking bays, plaza dimensions, building lines
DrainagePer module (an inverted umbrella drains itself) or to shared valley gutters
ExtensionDesigned so more bays can be added later to the same detail
FoundationsIsolated footings to IS 456, one type repeated, sized for wind uplift
ScopeSurvey, 3D design, engineering, fabrication, installation and tensioning — one in-house team

General membrane figures — life, translucency, fire class — are manufacturer values for the material type, set out on the membrane materials page.

Membrane

Membrane options

Modular canopies use PVC or PVDF for most work. Because every panel is cut to the same pattern, fabrication is efficient and repeatable.

Standard

PVC-coated polyester

The most economical choice and the widest colour range; blocks the rain, hail and almost all UV. PVC fabric →

Upgrade

PVDF-lacquered PVC

The same base with a tougher top-coat that stays cleaner under dust and pollution. PVDF fabric →

Premium

PTFE-coated glass

Non-combustible and near self-cleaning, with the longest service life. PTFE fabric →

A full comparison of the fabrics — translucency, fire class, typical life — is on the membrane materials page.

Design, Engineering & Build

How it is engineered and built

The governing load

One module is form-found and analysed for the worst-case bay — wind uplift, dead and rain load — and then that design is repeated. The frame is designed to IS 800 and the footings to IS 456, with wind to IS 875 Part 3.

Why modular is fast

There is one bay to fabricate and one erection sequence to repeat, so the programme is short and predictable, and adding bays later is straightforward.

Steel & foundations to code

The frame is designed to IS 800 and the footings to IS 456, checked for uplift and overturning. Galvanising to IS 4759 / IS 2629 for corrosion protection.

Built off-site, raised fast

Steel is cut, welded and galvanised in the workshop and the membrane is cut and welded into panels, while the footings are cast on site. On-site work is then quick and low-disruption.

One accountable team

Survey, 3D design, engineering, fabrication, installation and tensioning are all Ekra Decor’s own team, with a handover pack of drawings, load report, stability certificate and material certificates.

Cost

What drives the cost

Cost is not a fixed rate per square foot — two structures of the same size can differ widely. The main factors:

Covered area / span Structural form Structure height Steel tonnage Membrane grade & colour Local wind zone Soil & foundation type Drainage strategy Integrated lighting Site access Working around live operations Bespoke detailing Number of modules Module type

Cost scales with the number of modules once the module is fixed. Send your area for a module recommendation and an itemised quote; see the cost guide.

Ownership

Looking after the structure

  • Cleaning — a periodic wash; PVDF and PTFE surfaces largely self-clean in rain.
  • Membrane & seams — check for abrasion, coating wear and seam lifting at the corners and edges.
  • Cable tension — a first re-tension after the initial season, then a periodic check.
  • Steel & connections — inspect the galvanising and the connections at ground level.
  • Drainage — keep the low points, gutters and outlets clear before the monsoon.
Common Questions

Modular tensile structure FAQ

The questions people ask about a canopy built from repeating bays.

A canopy built from one pre-engineered bay or unit — a barrel-vault bay, a conical module, an inverted umbrella — repeated to cover the area. The design work is done once, for one module.

There is one bay to fabricate and one erection sequence to repeat, so the programme is short and predictable. It also makes extending the canopy later straightforward.

Yes — a modular canopy is designed so more bays can be added later to the same detail, as parking or a plant grows.

No. One module is fully form-found and analysed for the worst-case bay; the engineering is the same, it is just not repeated for every bay.

Repeating barrel-vault bays, conical module grids, inverted umbrellas, and hypar bay arrays. The choice depends on the shape of the area and the drainage.

PVC or PVDF for most projects. Because every panel is cut to the same pattern, fabrication is efficient.

Cost scales with the number of modules once the module is fixed. Send your area for a module recommendation and an itemised quote.

Send us the area to cover

You get a module recommendation, a count and an itemised quote.

Get in touch

Let’s Build Your Structure

Speak directly with our structural engineering team to discuss your project dimensions, material options, or to schedule a free on-site technical inspection across India.

  • 28+Years experience
  • Pan-IndiaTurnkey execution
  • ISO9001:2015 certified

Request an itemised price quote

Fill in your requirements below for a free engineering assessment & itemised estimate.

* required — everything else is optional

An engineer reviews the brief and calls you back — usually within a few hours during office hours (9 AM–6 PM, Mon–Sat).

Your details are used only to respond to this enquiry.

Chat with an Engineer on WhatsApp
Call Now WhatsApp Email Us
WhatsApp Call Now