Direct Hotline: +91 98102 37952
Rangpuri Near Shiv Murti, NH-8, New Delhi
ISO 9001:2015 Certified Manufacturer
A large-span retractable tensile membrane roof on a truss-and-rail system over a rooftop terrace, membrane bays partly open against a dusk sky
Retractable Roof Systems

Retractable Roof Systems Manufacturer

Engineered retractable roofing systems designed to transform large-span spaces between covered and open-air environments — the primary steel structure stays fixed; only the membrane bays travel.

Reviewed by Mukesh Mittal, Senior Structural Engineer · Last updated: 14 September 2026

DesignEngineeringFabricationInstallation
Long-axis view of a 3D design model of a multi-bay barrel-vault retractable membrane roof, membrane partly drawn back over the steel frame
3D structural design model — illustrative of the system geometry, not a photograph of a completed project.
Engineered Flexibility

A Roof That Adapts
to the Space

A retractable roof system lets a large space operate as a protected indoor environment or an open-air environment, depending on operational requirements and the weather.

The fixed elements — foundations, columns and the primary steel frame — carry every load at all times. The membrane-carrying roof bays are the only part that moves, travelling along a fixed guide system between positions.

OpenNatural ventilation & open-air operation
ClosedWeather & shade protection
PartialControlled opening & flexible operation
System Movement

How a Retractable Roof Works

One structure, three states. The membrane bays travel along the eave guide rail and stack at the parking end; the primary structure never moves.

Closed

Membrane sections provide full overhead coverage across the opening.

Partial

Moving roof sections retract along the guide system toward the parking end.

Open

The roof sections are positioned clear of the opening; the floor is open to the sky.

System Anatomy

Twelve Systems, One Load Path

Every component of a large-span retractable roof, from the membrane surface down to bearing ground. Select a component to highlight it.

Component set shown where applicable to this membrane and frame type. The confirmed configuration and hardware for any project are issued at detailed engineering and shop-drawing stage.

Foundation to Roof

One Continuous
Load Path

Every load on the roof — self-weight, wind, and the mechanical forces of retraction — follows one uninterrupted path from the membrane surface down to bearing ground. The retractable bays introduce a single moving link, the rail and carriage; every other stage behaves as a conventional fixed-steel load path.

  1. MembraneSurface load and wind pressure
  2. Moving frameCollects each bay's load
  3. Guide rail & carriageThe one moving link in the path
  4. Primary steelEave trusses and bracing
  5. ColumnVertical and lateral transfer
  6. Base plate & anchor rodsLoad spread and hold-down
  7. RCC foundationInto the ground-bearing strata

Final structural dimensions, connections and foundation design are determined through project-specific engineering calculations and site conditions.

Labelled reference diagram of a steel column base: column, base plate, anchor rods, grout pad and concrete footing
Column base — engineering reference. Column → base plate → anchor rods → grout pad → RCC footing → ground.
The Mechanism

Precision Behind
Every Movement

The movement system is engineered to guide the retractable roof sections along their designed travel path — a motorised carriage per bay, engaging the fixed rail, with travel synchronised across all moving bays.

Design-model close-up of a drive carriage on the eave truss guide rail, with the toothed rack visible along the running line
Drive carriage on the eave rail. Illustrative model — final drive configuration (motor, gearbox, and whether travel is by drive wheel, rack, chain or cable) is confirmed at detailed engineering.
Structural System

The Frame Carries
Everything

The fixed steel skeleton — columns, eave trusses and rafter framing — carries the entire roof, moving and stationary, down to the foundations. Bracing and connection plates tie every member into one continuous, laterally stable frame.

Underside wireframe view of a 3D design model, showing the full barrel-vault truss and purlin framework spanning the columns
Underside of the primary and secondary steel — design model.
Fixed

Primary steel

Columns, eave lattice trusses and main cross-bracing — sized for the span, the wind zone and the connections.

Fixed

Secondary members

Rafter framing and purlins between the primary trusses, supporting the membrane bays.

Fixed

Bracing

Ties the frame into one laterally stable structure against wind and the forces of retraction.

Moving

Moving frame & rails

The retractable sub-frames and the eave-mounted guide rails they travel on — the only elements that move.

Structural coordination, member sizes, load transfer and connection design are established through project-specific engineering against the site and the applicable codes — not assumed at concept stage.

Membrane Technology

The Membrane Is
Part of the Engineering

Material selection is not a finish choice made at the end — it is set by the span, the retractability, and the environment the roof has to work in.

A

PVC-coated polyester

Economical, widely used, and workable for retractable panels that must pleat and re-tension. PVC membrane →

B

PVDF-coated membrane

A PVC base with a PVDF surface treatment — enhanced durability, better self-cleaning, a longer surface life. PVDF finish →

C

PTFE-coated fibreglass

High durability, high translucency and a long service life — where the project justifies it. PTFE membrane →

D

ETFE systems

A foil-based envelope, used where project requirements justify it rather than a woven membrane. ETFE film →

The right material for a retractable roof depends on span, retractability, durability, UV exposure, translucency, fire performance, environmental conditions, maintenance and architectural requirements. It is not the case that every material applies to every retractable roof. See the full membrane material guide and how long each membrane lasts.

Connection Detail

Where the Fabric
Meets the Frame

Each fabric panel terminates at the moving frame line through a build-up of components that carry the tension and keep the joint watertight.

  1. Membrane edgeThe fabric panel terminates at the moving frame line
  2. Edge reinforcementA reinforced fabric strip or webbing along the termination edge
  3. Edge cable / tensioning componentMaintains fabric tension along the edge run
  4. Clamp / profileAn aluminium or steel clamp plate securing the edge
  5. FastenersMechanical fixings through the clamp into the structural member
  6. Steel / moving frameThe retractable rafter or cross-member carrying the bay
Weather & Drainage

Water Follows the Geometry

The barrel-vault bay curvature sheds rainwater toward the eave and valley lines, where it is collected and carried clear of the structure and the floor below — in every roof position, closed or open.

Roof geometry and the drainage layout are coordinated at detailed design stage so water does not accumulate on the roof in any position. Design also considers wind, rain, environmental exposure and operational conditions — the specific figures are established by project engineering, not assumed.

Control & Automation

Commanded and Monitored

A deliberate command from an operator initiates movement; safety logic and monitoring sit between that command and the drive at all times.

  1. OperatorLocal or centralised command interface
  2. Control systemControl panel and operator logic
  3. Safety logicInterlocks and permissives checked first
  4. Motor controlMotor controllers per bay
  5. Drive systemSynchronised travel across bays
  6. Retractable roofMonitored movement to position
Command

Control panel & motor controller

The operator interface and the per-bay drive controllers.

Feedback

Limit switches & position sensors

Define the open and closed travel limits and confirm each bay's location on the rail.

Protection

Emergency stop & safety interlocks

Immediate halt from any station; prevention of conflicting or unsafe commands.

Optional

Weather sensors

Wind- or rain-triggered response, where specified for the project.

Safety

Designed Around
Controlled Movement

Emergency stop

Immediate halt of roof travel from any operator station, at any point in the cycle.

Limit switches

Automatically stop travel at the defined open and closed positions.

Mechanical end stops

A physical backup limiting carriage travel beyond the designed range.

Motor protection

Monitors drive load and halts operation outside safe operating parameters.

Safety interlocks

Prevent simultaneous or conflicting commands across the drive system.

Position monitoring

Synchronised, monitored travel across all retractable bays.

The final safety architecture — device selection, redundancy and interlock logic — is project-specific and confirmed during detailed engineering and the automation design.

Applications

Where Large-Span
Retractable Roofs Fit

Wherever one venue has to work as both a covered and an open-air space. Suitability for any specific project is confirmed through structural, mechanical and code review.

Large-span retractable membrane roof over a stadium-scale floor plate, 3D design model
Sports Venues
Long multi-bay membrane roof suited to event spaces, 3D design model
Event Spaces
Barrel-vault membrane roof structure over an exhibition-scale span, 3D design model
Exhibition Centres
Column-free covered floor under a retractable membrane roof, suited to multipurpose halls, 3D design model
Multipurpose Halls
Steel framework of a large membrane roof suited to commercial developments, 3D design model
Commercial Developments
Retractable membrane roof over an industrial-scale floor, 3D design model
Industrial Facilities

Also suited to public spaces and entertainment venues. All images are 3D design models illustrating the system type — not photographs of completed projects.

Before You Specify

Two Decisions That Come First

The system described on this page is motorised and large-span. Two questions sit earlier than any of the engineering above — how the roof is driven, and what the moving panel is made of. Both are worked through in detail separately.

Why Retractable

One Venue,
Every Condition

01

Flexibility

Switch between covered and open-air operation on command.

02

Weather Adaptability

Provide overhead protection when it is required, and open up when it is not.

03

Architectural Impact

Create a distinctive large-span architectural roof, not a utilitarian cover.

04

Space Utilisation

Allow one venue to support multiple operating conditions across the year.

Ekra Decor Capability

From Concept
to Commissioning

Every discipline a retractable roof needs — structural steel, membrane and mechanical — delivered under one accountable team, practised since 1998.

01

Site Study

02

Concept Design

03

3D Modelling

04

Structural Engineering

05

Steel Fabrication

06

Membrane Fabrication

07

Mechanical System

08

Installation

09

Testing

10

Commissioning

11

After-Sales Support

Technical FAQ

Retractable Roof — Questions

What is a retractable roof?
A retractable roof is a permanent steel structure carrying a moving fabric envelope. Motorised roof sections travel along a fixed guide system, allowing a covered floor to transition, on command, between a weather-protected enclosure and an open-air space — without dismantling any part of the primary structure.
How does a motorized retractable roof work?
Each membrane bay is carried on a light steel moving frame with roller-wheel carriages at each end that engage a fixed guide rail on the eave truss. A motorised drive per bay moves it along the rail, with travel synchronised and monitored across all bays. The bays stack at a parking end when the roof is open; the primary structure never moves.
What materials can be used for retractable membrane roofs?
PVC-coated polyester, PVDF-coated membrane, PTFE-coated fibreglass, and ETFE foil systems where appropriate. The choice is set by the span, the retractability, durability, UV exposure, translucency, fire performance, the environment, maintenance and the architectural requirement — it is not the case that every material suits every retractable roof.
Can retractable roofs cover large-span spaces?
Yes. At building and stadium scale the roof is a permanent steel frame on a perimeter column grid carrying motorised membrane bays. The clear span, bay count, structural sizes and foundation design are all established by project-specific engineering against the site and the applicable codes.
How is the retractable roof controlled?
Through a control panel and per-bay motor controllers, with limit switches and position sensors defining and confirming travel, an emergency stop at every operator station, and safety interlocks preventing conflicting commands. Weather sensors that trigger a wind- or rain-response can be added where specified.
What factors determine the structural design?
Project requirements and site conditions, structural calculations, wind and rain loading, the operational requirements of the roof, the applicable standards and codes, the material specification, and the mechanical and electrical-safety requirements. These are confirmed at detailed engineering rather than assumed at concept stage.
How is the membrane maintained?
Periodic cleaning, visual inspection, and inspection of the seams, edges and tension across all bays — alongside inspection and lubrication of the rails, rollers, bearings and drive system, and testing of the control panel, sensors and emergency systems. Ekra Decor provides a maintenance schedule with every project.
How long does installation take?
It is project-specific — a function of the span, the number of bays, the steel tonnage and the mechanical scope. On-site work is planned around a pre-fabricated steel frame and pre-fabricated membrane panels to keep the sequence efficient; the programme is confirmed once the project is engineered.
Start a Project

Planning a Retractable Roof Project?

Share your project requirements with our team for a concept discussion and a project-specific solution — structure, mechanism, membrane and controls, from one team.

Get In Touch

Let’s Build Your Structure

Speak directly with our structural engineering team to discuss your project dimensions, material options, or to schedule a free on-site technical inspection across India.

Direct Phone & WhatsApp Hotlines

+91 98102 37952 (Delhi HQ) / +91 93159 45187 (Bangalore) / +91 82879 92289 (Engineering)

Official Email Address

info@ekradecor.com

Delhi Factory & Administrative HQ

No. 367 Badam Singh Market, Rangpuri, Near Shiv Murti, NH-8, New Delhi 110037

Bangalore Regional Office

93/5, Kada Agrahara Village, Dodda Gubbi Post, Bangalore, Karnataka - 560077, India

Chattarpur Office

House No. 488, 3rd Floor, Khasra No. 60, 100 Futa Road, Opposite Delhi Jal Board, Near Diwan Bajaj Showroom, Chattarpur Pahari, New Delhi - 110074, India

Get Directions

Request Itemized Price Quote

Fill in your requirements below for an instant engineering assessment & 3D estimate.

An engineer reviews the brief and calls you back

or reach us directly
Chat with an Engineer on WhatsApp
28+ Years Experience
Pan-India Turnkey Execution
ISO 9001:2015 Certified
Call Now WhatsApp Email Us
WhatsApp Call Now