Direct Hotline: +91 98102 37952
Rangpuri Near Shiv Murti, NH-8, New Delhi
ISO 9001:2015 Certified Manufacturer
Cantilevered car-parking tensile canopy at an industrial facility in Manesar, Haryana, built by Ekra Decor
ESTABLISHED 1998 DESIGN · FABRICATION · INSTALLATION

Car Parking Tensile Shade Manufacturer

Ekra Decor designs, fabricates and installs cantilevered tensile canopies over car parking — a PVC or PVDF membrane on a galvanised steel frame that keeps the bays column-free and the vehicles out of the sun, rain and hail. In-house since 1998.

  • Column-free bays — cantilever frame
  • Single-row, butterfly & multi-bay layouts
  • Concealed column drainage
  • Engineered to IS 875, IS 800 & IS 456
Practising since 1998
ISO 9001:2015 certified
Design to maintenance, one team
Pan-India project execution
Trusted Nationwide

Engineering Trusted by India’s Leading Names

28+ years delivering tensile structures for corporate campuses, industrial groups, and institutional developments — built with fabric technology from the world’s leading membrane manufacturers.

Corporate & Institutional Clients
Material Technology Partners
Layout & Bays

How a car parking tensile shade is laid out

A car parking shade is almost always a cantilever: one bank of columns along the back of the bays, and a clear front edge over the drive aisle so nothing blocks a door opening or a reversing car. Everything else — span, height, drainage — follows from the parking layout.

Bay module

A standard car bay is about 2.5 m wide and 5 m long. The structure spans several bays between columns. A single row covers one bank of cars; a back-to-back double row shares a central valley gutter (the “butterfly” section); large lots use a multi-bay grid.

Clear height

2.1 to 2.2 m at the low front edge is enough for cars. Raise it where SUVs, pickups or roof-boxes are expected — and remember a taller structure catches more wind and needs a heavier frame.

The fabric

A PVC-polyester or PVDF membrane blocks almost all UV and all the rain and hail. A light colour keeps the underside cooler. The cover also keeps bird droppings, tree sap and morning dew off the paintwork.

Drainage

Water runs to the low front edge, or into a valley gutter between back-to-back rows, and is piped down inside a column — never left to drip into the aisle where people walk.

Foundations and lighting

Isolated footings, sized mainly for wind uplift because the roof is so light. Light fittings bolt to the steel and the wiring runs in the columns.

Related: covered car parking for a weathertight roof, vehicle parking structures for larger vehicles. See completed car parks or send your layout.

Configurations

Car-park canopy layouts

The layout follows the parking plan. Four arrangements cover almost every site.

Single row (cantilever)

One line of columns behind the bays; the membrane cantilevers forward over the cars and the drive aisle. The default for a single bank of parking against a wall or boundary.

Back-to-back “butterfly”

Two rows of bays share one central column line and a valley gutter between them. The most efficient use of steel per car for an open lot.

Multi-bay grid

A repeating grid of frames covers a large lot in both directions, with the column line running down the aisles so the bays stay clear.

Conical / hypar feature

Where the parking is a forecourt or an entrance drop-off, a conical or saddle canopy gives cover with a more architectural roofline.

For a fully weathertight roof over parking — a sealed membrane with no open front edge — see covered car parking. For buses, trucks and plant, see vehicle parking structures; for staff motorcycles and scooters, two-wheeler parking sheds.

Specification & Options

What is specified on a car-park canopy

There is no single fixed spec — the structure, membrane and finish are recommended after the site, layout, local wind and budget are reviewed. The choices involved:

Car-park tensile canopy — specification choices
ElementOptions
StructureCantilever (single row), butterfly (back-to-back), or a multi-bay grid; conical / hypar for a forecourt (fuel stations have their own brief — see forecourt canopies)
MembranePVC-coated polyester for most work; PVDF-lacquered for a cleaner, longer-lasting finish; PTFE-glass where a permanent, non-combustible roof is wanted
FrameStructural or mild steel, hot-dip galvanised (and painted where the site is coastal or industrial); stainless fittings and cables where exposure is aggressive
Clear heightSet from the vehicles — higher for SUVs, pickups and roof-boxes; a taller canopy catches more wind and needs a heavier frame
CoverageA single carport bay up to a multi-hundred-bay lot
DrainageTo the low front edge, or a valley gutter between rows, piped down inside a column — never dripping into the aisle
FoundationsIsolated footings to IS 456, sized mainly for wind uplift because the roof is so light
LightingFittings bolt to the steel; wiring runs concealed inside the columns
ScopeSite survey, 3D design, fabrication, installation, tensioning and maintenance support — one in-house team

General membrane figures — service life, translucency, fire class — are manufacturer values for the material type, set out on the membrane materials page. The engineered values for a given canopy (steel sizes, cable forces, foundation sizes) come out of the structural design for the actual site and loads.

Membrane

Fabric options for a car-park canopy

Almost all car-park work is done in a PVC-based membrane. The choice is really about how long the finish has to keep looking new.

Standard

PVC-coated polyester

The most economical option and the widest colour range. Blocks the rain, hail and almost all UV; a light colour keeps the underside cooler. PVC fabric →

Upgrade

PVDF-lacquered PVC

The same base with a tougher top-coat that stays cleaner for longer under dust and pollution — worth it on a corporate or public lot. PVDF fabric →

Premium

PTFE-coated glass

Non-combustible and near self-cleaning, with the longest life. Usually reserved for landmark or high-fire-class projects. PTFE fabric →

A full comparison of the fabrics is on the membrane materials page.

Design, Engineering & Build

How the canopy is engineered and built

Wind is the governing load

A tensile roof weighs almost nothing, so the design case is wind uplift, not gravity. The membrane is form-found into double curvature so it stays taut and cannot lift, and the frame and footings are sized for the site’s design wind pressure under IS 875 Part 3.

Steel & foundations to code

The frame is designed to IS 800 and the isolated footings to IS 456, checked for uplift and overturning. Galvanising to IS 4759 / IS 2629 for corrosion protection.

Built off-site, raised fast

Steel is cut, welded and galvanised in the workshop and the membrane is cut and welded into panels, while the footings are cast on site. Erection is then quick — stand the frame, run the membrane, tension it — with little disruption to the parking.

One accountable team

Survey, 3D design, fabrication, installation and tensioning are all Ekra Decor’s own team, with a handover pack of drawings, load report, stability certificate and material certificates.

Cost

What drives the cost of a car-park canopy

Cost is not a fixed rate per bay or per square foot — two lots of the same size can differ widely. The main factors:

Number of bays Layout (single / butterfly / grid) Span between columns Clear height Membrane grade Steel tonnage Local wind zone Soil & foundation type Drainage & gutters Integrated lighting Site access & craneage Working around a live car park

Send your parking layout and we return a design direction and an itemised quote. More on what moves the number is in the tensile structure cost guide.

Ownership

Looking after a car-park canopy

  • Cleaning — a periodic wash; PVDF surfaces largely self-clean in rain, plain PVC benefits from an occasional wipe-down of dust and tree debris.
  • Membrane check — look over the fabric and seams for abrasion or lifting, especially at the front-edge cable and the corners.
  • Cable tension — a first re-tension after the initial season, then a periodic check.
  • Drainage — clear the front-edge gutter, valley gutters and column downpipes of leaves before the monsoon.
  • Steel & bolts — inspect the galvanising and the connections, particularly at ground level.
Common Questions

Car parking tensile shade FAQ

The questions people ask before commissioning a car-park canopy.

A canopy that carries its load in a tensioned membrane rather than a solid roof. A PVC or PVDF fabric is stretched over a galvanised steel frame — almost always a cantilever, with columns behind the bays and a clear front edge over the drive aisle.

So nothing blocks a car door or a reversing vehicle. One line of columns sits behind the bays and the roof reaches forward over the cars and the aisle, leaving the parking completely column-free.

About 2.1–2.2 m at the low front edge is enough for cars. It is raised where SUVs, pickups or roof-boxes are expected. A taller canopy also catches more wind and needs a heavier frame.

A single-row cantilever sheds rain to its low front edge; a well-designed one keeps the bays dry in normal rain but is open at the front. For a fully sealed roof with no open edge, see covered car parking.

PVC-coated polyester for most projects, PVDF-lacquered PVC where the finish must stay clean for longer, and PTFE-glass for permanent or high-fire-class structures. All block the rain, hail and almost all UV.

To the low front edge, or into a valley gutter between back-to-back rows, then piped down inside a column. It is never left to drip into the aisle where people walk.

There is no fixed rate per bay or per square foot. Cost is driven by the number of bays, the layout, the span, the clear height, the membrane grade, the wind zone, the soil and site access. Send your layout for an itemised quote.

Yes. The steel and membrane are fabricated off-site, so on-site work is limited to casting footings and erecting the frame. Sections of the lot are fenced and handed back as they are finished.

Isolated concrete footings, designed to IS 456 and sized mainly for wind uplift because the roof weighs so little.

The steel frame, properly galvanised, lasts for decades; the membrane is the wearing part — manufacturers typically quote 15–20 years for PVC, longer for PVDF. Maintenance is periodic cleaning, a membrane and cable check, and clearing the gutters before the monsoon.

Yes — see two-wheeler parking sheds for motorcycles and scooters, and vehicle parking structures for buses, trucks and plant.

Send us your parking layout

You get a design direction and an itemised quote — not a price per bay.

Get In Touch

Let’s Build Your Structure

Speak directly with our structural engineering team to discuss your project dimensions, material options, or to schedule a free on-site technical inspection across India.

Direct Phone & WhatsApp Hotlines

+91 98102 37952 (Delhi HQ) / +91 93159 45187 (Bangalore) / +91 82879 92289 (Engineering)

Official Email Address

info@ekradecor.com

Delhi Factory & Administrative HQ

No. 367 Badam Singh Market, Rangpuri, Near Shiv Murti, NH-8, New Delhi 110037

Bangalore Regional Office

93/5, Kada Agrahara Village, Dodda Gubbi Post, Bangalore, Karnataka - 560077, India

Chattarpur Office

House No. 488, 3rd Floor, Khasra No. 60, 100 Futa Road, Opposite Delhi Jal Board, Near Diwan Bajaj Showroom, Chattarpur Pahari, New Delhi - 110074, India

Get Directions

Request Itemized Price Quote

Fill in your requirements below for an instant engineering assessment & 3D estimate.

An engineer reviews the brief and calls you back

or reach us directly
Chat with an Engineer on WhatsApp
28+ Years Experience
Pan-India Turnkey Execution
ISO 9001:2015 Certified
Call Now WhatsApp Email Us
WhatsApp Call Now